Gas boiler mounted on a kitchen wall among the kitchen units

If your boiler pressure drops once, there may be a simple explanation. A boiler losing pressure repeatedly usually means water is escaping from the heating system somewhere, or a part is not doing its job. Either way, a pressure loss that keeps coming back needs a heating engineer to find the cause.

This guide explains what boiler pressure is, what can cause repeated loss, and what to note down before you book a repair.

What is boiler pressure?

Most combi and system boilers are connected to a sealed system. That means the water in the boiler, pipes and radiators is closed off from the mains and held under a little pressure, which the boiler needs to work properly.

The boiler shows this pressure on a dial or display. If it falls too low, many boilers stop and show a fault code or warning light to protect themselves. Small changes are normal: water expands as it heats, so pressure is usually a bit higher when the heating is running than when the system is cold. A part called the expansion vessel absorbs that extra volume and helps keep the pressure stable. (Vaillant: what is an expansion vessel?)

What should the pressure be?

The correct range depends on your make and model, so check your own boiler’s user manual. Some gauges also mark the normal zone.

As an example only: Viessmann says most sealed systems run at around 1.0 to 1.5 bar. (Viessmann: boiler loses pressure) Your boiler may differ.

A white cast-iron column radiator standing against a wall; a leak at a radiator or its pipework is one reason for a boiler losing pressure
A cast-iron column radiator. Photo: Dominic Alves, Wikimedia Commons, CC BY 2.0.

Can I top up the pressure myself?

Some manufacturers’ manuals describe topping up the pressure as a task a householder can do. Your boiler’s user manual explains whether this is a user task for your model. If it does not, or you are unsure, leave it to an engineer.

Topping up is not a repair. If you keep needing to, the cause is still there. Ideal also notes that repeatedly topping up with fresh mains water can dilute the inhibitor, the chemical added to heating water to help slow internal corrosion. (Ideal Heating: why is my boiler losing pressure?)

Why is my boiler losing pressure?

Only an engineer can confirm the cause, but manufacturers describe several common possibilities.

A leak in the pipework or radiators

Water can escape from joints, radiator valves or fittings. Small leaks are easy to miss, because water dripping onto warm pipework can evaporate before it forms a puddle. Signs can include damp patches, staining, rust marks or flaking paint near radiators and pipes. (Baxi: why is my boiler pressure low?; Vaillant: why is my boiler losing pressure?)

The pressure relief valve discharging

The pressure relief valve is a safety part that opens to let water out if pressure gets too high, then closes again. If it is worn or blocked by debris, it can let water out when it should not. (Viessmann: what does a pressure relief valve do?) Ideal notes that a wet outlet pipe from the valve is a sign of a problem that needs an engineer. (Ideal Heating: why is my boiler losing pressure?)

Do not guess which pipe is the valve outlet: other pipes, such as the condensate pipe, can look similar. If you are unsure, just tell the engineer what you have seen.

An expansion vessel problem

If the expansion vessel loses its air charge, or its internal rubber diaphragm fails, it can no longer absorb expansion properly. Pressure may then swing more than usual as the system heats and cools, and the relief valve may release water. Checking, recharging or replacing the vessel is engineer work. (Ideal Heating; Vaillant: expansion vessel; Viessmann: pressure relief valve)

Recent work on the system

Bleeding radiators releases air and some water, so pressure can drop afterwards. (Vaillant: why is my boiler losing pressure?) Work such as changing a radiator or moving pipework can also disturb joints. A drop that continues weeks later still needs investigating.

A hand writing notes in a notebook
Noting readings, times and symptoms before you call helps the engineer. Photo: Kristin Hardwick, Wikimedia Commons, CC0.

What to note down before you call

You do not need to touch anything. A short record helps the engineer narrow down the cause.

  • Pressure readings. Note the figure and the time, ideally when the system is cold and again when the heating has been running for a while.
  • How often it drops. Does it fall over hours, days or weeks? If your manual permits topping up and you have done so, note when.
  • Fault codes. Write down or photograph any code or warning light.
  • Anything you can see. Look, without touching, for damp patches, drips, stains or rust marks around radiators, visible pipes and under the boiler. Take a photo if you can.
  • Recent work. Mention radiators bled, changed or added, new flooring, building work, or a recent boiler service or repair.

Our guide to safe checks before you call an engineer covers what else to note, including your boiler make and model, if it has stopped altogether.

When to arrange a repair

Book a repair visit if:

  • the pressure keeps falling below the range in your manual;
  • you have had to top up more than once in a short period, or the boiler keeps stopping with a low-pressure fault code;
  • you can see damp, drips or staining you cannot explain;
  • the pressure rises well above the normal range when the heating is on.

Stop and call straight away if water is leaking from the boiler itself, or water is near sockets, switches or other electrics. Do not touch the electrics. Never open the boiler casing: work on gas appliances must be done by a Gas Safe registered engineer.

If you smell gas at any point, call the National Gas Emergency Service on 0800 111 999, free and open 24 hours a day. (Cadent: what to do if you smell gas)

Hands holding a smartphone beside a cup of coffee
Have your notes and the boiler make and model ready when you call. Photo: Pixel.la Free Stock Photos, Wikimedia Commons, CC0.

Common questions

My boiler is losing pressure but I can’t see a leak. Why?

Not every cause is visible. A leak may be under floorboards or inside the boiler, small drips may evaporate from warm pipes, and a relief valve or expansion vessel fault may not show as an obvious puddle. That is why it needs a diagnosis, not repeated top-ups.

Will a boiler service fix it?

A boiler service is routine maintenance. If the pressure is already dropping, book a repair visit so the engineer can look for the specific cause first.

Need help in Cambridge?

Our Gas Safe registered engineers cover Cambridge and the surrounding villages. If your boiler has stopped working, call our 24/7 emergency line on 07444 915095. If the pressure is dropping but the heating is still running, send us an enquiry with your notes, or see our boiler repair page.

Call 07444 915095

Main image: a gas boiler fitted among kitchen units. Photo: Turbojet, Wikimedia Commons, CC BY-SA 4.0. Photos from Wikimedia Commons are not of Cambridge Climate Solutions properties, jobs or engineers.

admin